LKSM-FRSHF2 0.6/1kV

Conductor
Stranded copper conductor 1.0-10 mm², IEC 60228 Class 2
Stranded copper conductor 16-300 mm², IEC 60228 Class 5
Insulation
Mica tape + XLPE, IEC 60092-360
Cabling
Cores twisted together. Fillers or dummy cores included in select sizes based on product specifications to obtain symmetrical and round construction, covered by separator tape
Bedding
Lapped tape
Armour
Copper wire braid, coverage > 90%, IEC 60092-350
Tinned copper wire braid on request
Rip cord
For conductors ≥ 16 mm²
Sheath
Thermosetting polyolefin SHF2, IEC 60092-360
Standard colour black, other colours on request
Application
Fire-resistant, armoured power and control cable. For fixed installation in most areas, and on open deck in ships and offshore units. For areas where oil resistant cable required. If the cable is exposed to direct sunlight, protective covering or cable with black outer sheath is recommended.
Core identification
Colour code for 1…4 core cables, number code for 5…37 core cables
Marine Type Approvals
ABS, BV, CCS, CRS, DNV, KR, LR, RINA
Rated voltage
AC 0,6/1kV (1.2 kV)
DC 0.9/1.5 kV (if voltage to earth does not exceed 0.9 kV)
Fire performance
IEC 60332-1-2
IEC 60332-3-22
Fire-resistant
IEC 60331-1 / IEC 60331-2 (180 min)
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Oil resistance
IEC 60811-404 conditions according to 60092-360/SHF2
Min. installation temperature
-15 °C
Operating temperature
-40 – 80 °C fixed installation
Max. Conductor temperature
90 °C