LKSM-EMC 0.6/1kV

Conductor
Stranded copper conductor 1.0-10 mm², IEC 60228 Class 2
Stranded copper conductor 16-300 mm², IEC 60228 Class 5
Insulation
XLPE, IEC 60092-360
Cabling
Cores twisted together. Fillers or dummy cores included in select sizes based on product specifications to obtain symmetrical and round construction.
Bedding
Lapped tape
Screen
Copper tape, coverage 100%
Armour
Copper wire braid, coverage > 90%, IEC 60092-350
Tinned copper wire braid on request
Rip cord
For conductors ≥ 16 mm²
Sheath
Polyolefin SHF1, IEC 60092-360
Standard colour black, other colours on request
Application
Armoured power and control cable. For fixed installation in most areas, and on open deck in ships and offshore units. Specially designed cables with screen for improved screening properties to address EMI/EMC problems.
Core identification
Colour code for 1…4 core cables, number code for 5…37 core cables
Marine Type Approvals
ABS, BV, CCS, CRS, DNV,KR, LR, RINA
Rated voltage
AC 0,6/1kV (1.2 kV)
DC 0.9/1.5 kV (if voltage to earth does not exceed 0.9 kV)
Fire performance
IEC 60332-1-2
IEC 60332-3-22
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Transfer impedance
IEC 61196-1
(typical value 26 dB over 1 mΩ/m at 100 MHz [20 mΩ/m])
Min. installation temperature
-15 °C
Operating temperature
-40 – 80 °C fixed installation
Max. Conductor temperature
90 °C