FXVDMSU

Central Element Glass Fiber (Ø mm)
Max 36 Fibers – Ø 3.3 mm
Max 48 Fibers – Ø 3.3 mm
PP-Slotted Core (Ø mm)
Max 36 Fibers – Ø 8.5 mm
Max 48 Fibers – Ø 9.5 mm
Optical Fibers
Max 36 Fibers – Ø 250 µmm
Max 48 Fibers – Ø 250 µmm
Wrapping
Aramid binding yarn
Water Blocking
Corrugated steel tape
Sheath
UV-protected and Halogen-free polyofefin plastic
Standard colour black
Other colours on request
Reference standard
Helkama specification
Application
Optical fiber cable for indoor/outdoor application and installation in marine, offshore and industrial use.
Tensile strength
Max
36 Fibres
Max
48 Fibres
Units Mechanical test
2500 2500 N IEC 60794-1-2 E1
Crush strength
Max
36 Fibres
Max
48 Fibres
Units Mechanical test
100 mm (PLATE) 7000 7000 N IEC 60794-1-2 E3
25 mm (MANDREL) 1500 1500 N IEC 60794-1-2 E3
Impact strength
Max
36 Fibres
Max
48 Fibres
Units Mechanical test
50 50 J IEC 60794-1-2 E4
Min. Bending Radius (Installation/fixed)
Max
36 Fibres
Max
48 Fibres
270/200 x Ø 300/230 x Ø
Nominal Outer Ø
Max
36 Fibres
Max
48 Fibres
Unit
13.5 15 mm
Cable Weight
Max
36 Fibres
Max
48 Fibres
Unit
180 210 kg/km
Marine Type Approvals
BV, DNV, RINA
Flame-retardant
IEC 60332-1-2
IEC 60332-3-22
Halogen-free
IEC 60754-1
Light Transmission
>60%, IEC 61034-1,2
Min. installation temperature
-15 ° C
Operating temperature
-30 – 70 °C