FIRELINE 750 500 V

Conductor
Solid or stranded copper conductor
Insulation
XLPE + Mica tape
Stranding
Conductors cabled together
Screen
Aluminium polyester tape
Sheath
LSZH Thermoplastic
Standard colour red
Reference standard
EN 50288-7
Application
Fire-resistant collectively screened instrumentation and control cable.
For fixed installation.
Core identification
2 cores blue and brown
3 cores brown, black, and grey
4 cores blue, brown, black, and grey
7-19 cores black numbers on white base
Min. Bending Radius (Installation/fixed)
9xØ∕4xØ
Rated voltage
500 V
Fire performance
IEC 60332-1-2
IEC 60332-3-22
Fire-resistant
IEC 60331-21
UV resistance
IEC 60068-2-5
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Min. installation temperature
-15 ° C
Operating temperature
-40 °C – 70 °C
Max. Conductor temperature
90 °C
Loop (pair, max 20 °C) (ohm/km)
1mm² – 18 Ω/km
1.5mm² – 12.1 Ω/km
2.5mm² – 7.4 Ω/km
Pair capacitance (nom. 1 kHz) (nF/km)
1mm² – 70 nF/km
1.5 mm² – 80 nF/km
2.5 mm² – 87 nF/km(@ 800 Hz)
Loop inductance (nom.) (mH/km)
1mm² – 0.67 mH /km
1.5 mm² – 0.68 mH/km
2.5 mm² – 0.63 mH/km